~JG - Graphing Sensor Calibration

Calibrates sensors and prints graphical sensor profile

~JG - Graphing Sensor Calibration

Overview

The ~JG command performs sensor calibration and prints a visual graph (media sensor profile) of the sensor values. Provides graphical feedback of sensor readings across label length for advanced troubleshooting and setup optimization.

Syntax

~JG

Parameters

None

Description

  • Performs full sensor calibration
  • Measures label length
  • Calibrates media and ribbon sensors
  • Prints graphical sensor profile
  • Visual troubleshooting aid

Examples

Generate Sensor Profile

~JG

Prints calibration data and sensor graph on label.

Graph Output

Shows:

  • Sensor readings across label
  • Media sensor threshold
  • Ribbon sensor threshold
  • Gap/mark detection profile
  • Sensitivity visualization

Uses for Graph

Troubleshooting

  • Identify sensor dead zones
  • Detect media reflectivity issues
  • Diagnose gap detection problems
  • Optimize sensor thresholds

Setup Verification

  • Confirm proper media detection
  • Validate gap positioning
  • Verify sensor alignment
  • Document baseline performance

Interpretation

Good Graph

  • Smooth curve across label
  • Clear gap detection
  • Consistent sensor readings
  • No anomalies

Problem Indicators

  • Flat line (sensor not detecting)
  • Inconsistent readings (alignment)
  • Reversed values (inverted sensor)
  • Spikes (debris or damage)

Usage Notes

  • Consumes one label for output
  • More detailed than ~JC
  • Provides visual reference
  • Useful for documentation
  • Keeps graph for records
  • ~JC - Set Media Sensor Calibration
  • ^SS - Set Media Sensors
  • ^MF - Media Feed