CommandsSensor calibration
~JC - Set Media Sensor Calibration
Recalibrates media and ribbon sensors
~JC - Set Media Sensor Calibration
Overview
The ~JC command forces a label length measurement and recalibrates both media and ribbon sensors. Ensures accurate media detection and proper label positioning after changing media types or when sensor readings drift.
Syntax
~JCParameters
None
Description
- Performs sensor calibration
- Measures label length
- Calibrates media sensor
- Calibrates ribbon sensor
- Feeds media during process
Examples
Recalibrate Sensors
~JCFull Setup After Media Change
~JCWhen to Calibrate
Required After
- Changing media type
- Installing new media roll
- Sensor drift detected
- Inconsistent feeding
- Media size change
Recommended
- Monthly for high-volume
- After media storage change
- When switching suppliers
- Seasonal (temperature change)
Calibration Process
- Send ~JC
- Printer feeds media
- Sensors measure and adjust
- Calibration data stored
- Printer ready to print
Usage Notes
- Printer will feed media during calibration
- Process takes several seconds
- In continuous mode: only media/ribbon sensors calibrated
- No label length measurement in continuous
- Essential for accurate printing
- Referenced in ^MF parameters
Related Commands
~JG- Graphing Sensor Calibration^SS- Set Media Sensors^MF- Media Feed^MN- Media Tracking